Prerequisites
- ✓Local water hardness test (council analysis or a test kit)
- ✓100 ml graduated cylinder
- ✓Technical data sheet of each product (dose range)
- ✓Technical data sheet for each washing machine (capacity, water consumption per cycle)
Step-by-step process
- 1
Define the target dose
Within the data-sheet range of 5–10 g/kg, according to soiling level (for Eco Wash, as specified by the Technical Service according to water hardness). Combine with machine capacity to obtain the target ml/cycle.
- 2
Configure the pump on the doser
Set the pulse time according to the doser manufacturer's table.
- 3
Test with a graduated cylinder
Disconnect the pump outlet tube and direct it into the cylinder. Run a full cycle. Measure the actual volume.
- 4
Adjust until the target is reached
If the actual volume does not match the theoretical one, change the pulse time and repeat the test.
- 5
Record and document
Log the product, pump, pulse time, actual volume and date on the calibration sheet. File it for future audits.
- 6
Repeat for each pump / each product
Detergent, fabric softener and bleach if used. Each is calibrated independently.
From grams per kilo to millilitres per cycle
Technical data sheets give the dose in grams per kg of dry laundry, but a measuring cylinder reads millilitres. To convert one into the other you need the product's density: ask the Technical Service for it, or weigh the volume you have collected in the cylinder on a set of scales. If you skip this step and calibrate in millilitres as if they were grams, the real dose will not be the one on the data sheet.
Which stage of the cycle each product goes in
Each pump must be connected to the washer signal for its stage. A product that goes in at the wrong stage does not do its job:
- Detergent (Bluegold, Biogold Q, Eco Wash): in the main wash, at around 40 ºC according to their data sheets.
- Sanitex: in the penultimate rinse, at 4 g/kg with a minimum contact time of 5 minutes.
- Fabric softener (Blue Soft, Hipo Soft): in the final rinse, at 5–10 g/kg.
- Oximatic +: 2–6 g/kg, always with an automatic peristaltic dispenser.
Before opening, run a cycle on each washer and check when each pump kicks in.
Common calibration mistakes
- Measuring with an empty tube: the first time, the pump has to be primed until product reaches the outlet; otherwise you are measuring air.
- Relying on a single measurement: repeat the test and go with a stable value.
- Crossed tubes: label each tube and each suction lance with the product name, so that a container change does not end with softener in the detergent inlet.
- Kinked or pinched tubes: they reduce the flow and the real dose ends up below the calibrated one.
- Not writing anything down: without the calibration record you will not know whether the pump has drifted over time.
When to recalibrate
The initial calibration is not for ever. Repeat the measuring-cylinder test when you change product or pack size, when you replace the pump tube, when you reprogramme the washer and when symptoms appear: too much or too little foam, laundry that smells or complaints about softness. The most frequent symptoms are covered in dosing problems and excessive foam.
Can I do the calibration myself?
Yes, with the measuring cylinder and following the steps in this guide. If you would rather the Technical Service did it, the pre-opening visit includes calibrating the pumps and training so that you can repeat it yourself.
Want the Technical Service to handle the initial calibration?
Pre-opening visit: on-site calibration and staff training.
B2B PRICE · MANUFACTURER
Shall we send you our detergent and softener price list?
Price per pack size for self-service laundries and recommended dosage. We will reply to your request.