Routine maintenance for your equipment
Machine Clean is a product for the routine care of washing machines with high descaling and sanitising power. Regular use eliminates the scale and odour-causing deposits that build up with continuous operation. Consistent results that prevent negative perceptions from your users.
High descaling power
Removes scale and odour-causing deposits
Eliminates bad odours
Removes sources of bad odours
Better results
Avoids negative perceptions from users
Practical format
1 L bottle · pack of 6×1 L
Routine use
Periodic maintenance
Dedicated cycle
40 g/kg · 60 °C · 30 min
Technical specifications
| Appearance | Clear, colourless liquid |
| pH (1%) | 2.0 ± 1.0 |
| Dosing | 40 g/kg with the washing machine empty, at 60 °C for approximately 30 min. Rinse thoroughly afterwards. |
| Format | 1 L · pack of 6×1 L |
| Components | Oxygen-based bleaches 5–15%. Hydrogen peroxide, acetic acid, peracetic acid |
| Precautions | H314 Causes severe skin burns and eye damage · H332 Harmful if inhaled · H335 May cause respiratory irritation · H411 Toxic to aquatic organisms. Keep away from heat. Wear full PPE. |
Step-by-step cleaning procedure
Machine Clean is used with the washing machine empty, in a dedicated maintenance wash. Do it with the machine out of service and no customers nearby: it is a corrosive product and its data sheet warns that it is harmful if inhaled.
- Put an "out of order" sign on the machine and ventilate the premises.
- Wear protective gloves, clothing and eye protection; if ventilation is inadequate, also wear respiratory protection.
- Check that the drum is empty.
- Add the product at the data-sheet dose, about 40 g/kg, and run a programme at around 60 °C for about 30 minutes.
- Rinse thoroughly with a rinse cycle before putting the machine back into service.
- Check that no product smell remains in the drum and remove the sign.
How often, and how to organise it
The data sheet refers to periodic care without setting a frequency. The practical approach is to draw up your own schedule based on how much each machine is used and to log it: the machines running the most cycles are the first to build up scale and sources of bad odours.
- Bring the cleaning forward if customers mention a musty smell, if you see residue on the door seal or if wash results worsen with no change in dosing.
- Schedule it during quiet hours or when the shop is closed.
- Record the date and machine in the same maintenance log you use for the dosing pumps.
Storage and safety
Machine Clean contains oxygen-based bleaching agents: hydrogen peroxide, acetic acid and peracetic acid. That is why its data sheet asks you to keep it away from heat, sparks and open flames, protect it from sunlight and store it in a cool place at temperatures not exceeding 50 °C.
- Keep it in the utility room, away from detergents and softeners and out of reach of the public.
- Do not mix it with other chemicals or add it to a wash containing laundry or detergent.
- It is toxic to aquatic life (H411): dispose of containers at a special or hazardous-waste collection point.
Which pack sizes are available?
A 1 L bottle and a 6×1 L pack.
Schedule routine maintenance for your equipment
We will help you set the ideal frequency based on wash volume and your local water hardness.
B2B PRICE · MANUFACTURER
Shall we send you our detergent and softener price list?
Price per pack size for self-service laundries and recommended dosage. We will reply to your request.